APC SRTL3000RMXLI Dubai

APC SRTL3000RMXLI Dubai

The APC SRTL3000RMXLI is a 3kVA / 2.7kW lithium-ion Smart-UPS On-Line rackmount UPS for servers, storage, firewalls, switches, and network racks that need clean double-conversion power. It is a 3U 230V unit with 6 IEC C13 and 2 IEC C19 outlets, SmartSlot management, and scalable runtime. Vector Digital Systems supplies, installs, and supports APC UPS systems across all 7 UAE emirates. WhatsApp your rack load and runtime target for a same-day quote.

WhatsApp for Price

Description

APC SRTL3000RMXLI Dubai 3kVA Li-ion UPS UAE

When the rack stays online, the business stays online

A server rack in Dubai rarely fails politely. Power dips, generator transfer delays, weak earthing, overloaded office circuits, tired batteries, and heat inside a closed network cabinet all show up at the worst time. The firewall reboots. The storage array throws alerts. The accounting server loses a write operation. The Etisalat or du handoff stays live, but the customer’s rack does not.

That is the moment where the UPS choice matters.

The APC SRTL3000RMXLI is built for that kind of rack. Not a desktop battery box under a table. Not a cheap standby UPS that waits for power to fail before reacting. This is a 3000VA / 2700W double-conversion online UPS, built in a 3U rackmount chassis, using lithium-ion battery technology and 230V output for servers, switches, storage, firewalls, and voice/data networks.

Vector Digital Systems supplies APC UPS systems for Dubai offices, JAFZA warehouses, DAFZA trading companies, clinic server rooms, school racks, and SME data rooms across all 7 UAE emirates. We size the UPS against the actual load. Not just the VA number on the box. Runtime, heat, rack depth, battery replacement cycle, bypass planning, and shutdown method all matter.

3000VA
2700W Output
3U
Rackmount UPS
Li-ion
Battery Platform

Lithium-ion online UPS for rack infrastructure

The SRTL3000RMXLI is different from older lead-acid 3kVA UPS models. It is a lithium-ion Smart-UPS On-Line unit with double-conversion topology, 3U rack height, 230V output, SmartSlot expansion, and C13/C19 outlets for mixed server and network loads.

What the APC SRTL3000RMXLI is built for

This UPS sits in the middle of a real IT rack. A Dell PowerEdge server. A NAS or SAN shelf. A firewall. Core switching. Internet routers. Maybe an IP PBX. Maybe a small CCTV recording server. Maybe a few PoE switches that should not drop when utility power flickers for two seconds.

That rack does not need the same power design as a full Khazna or Equinix DX1 cage. It still needs clean, stable power. And it needs enough runtime to ride through short interruptions, generator transfer, or controlled shutdown.

The SRTL3000RMXLI is a good fit when your load is below 2700W and you want online power protection rather than basic line-interactive backup. Double-conversion means incoming AC is converted and regulated before being delivered to connected equipment. The UPS is always conditioning the output. That matters for servers, storage, firewalls, and switches that do not like dirty power.

For Dubai offices, the practical buyer profile is clear. You have one to three server racks. Your IT room may be a proper cooled room, or it may be a converted office with split AC and a 42U rack. You have Etisalat Business or du Enterprise connectivity. Users expect the ERP, shared files, accounting system, Wi-Fi controller, VPN, and security gateway to stay live. You are not buying a UPS because the spec sheet looks nice. You are buying time. Time to keep running. Time to shut down. Time to avoid corrupted data.

That is where a lithium-ion 3kVA online UPS makes sense.

APC SRTL3000RMXLI specifications

Specification Detail
Brand APC by Schneider Electric
Model SRTL3000RMXLI
UPS Type Smart-UPS On-Line, double-conversion
Rated Power 3000VA / 2700W
Input Voltage 230V main; 220V and 240V supported
Output Voltage 230V main; 220V and 240V supported
Output Connections 6 × IEC C13 + 2 × IEC C19
Input Connection IEC 60320 C20
Rack Height 3U
Battery Type Lithium-ion
Battery Voltage 48V
Battery Recharge Time 4 hours
Battery Life 5 to 10 years
Management SmartSlot, USB compatible, audible and visible alarms, EPO
Dimensions 12.8cm H × 43.2cm W × 63.9cm D
Net Weight 30.5kg
Noise 50 dBA
Heat Dissipation 317 BTU/hr
Operating Temperature 0°C to 40°C
Warranty 5-year repair or replace listed in datasheet; UAE warranty to be confirmed at quotation

Do not confuse SRTL3000RMXLI with SRT3000RMXLI

The SRTL3000RMXLI is the lithium-ion 3U model with 6 C13 and 2 C19 outlets. The SRT3000RMXLI is a different 2U lead-acid model commonly listed online. When requesting a quote, use the full model number.

Why 3000VA does not mean 3000W

A common mistake in UPS buying is to read 3000VA as 3000W. That is not how this model is rated. The SRTL3000RMXLI is a 3000VA UPS with a 2700W maximum power rating. The watt figure is what matters when you add up the real load from servers, storage, firewalls, switches, routers, and rack PDUs.

For example, a rack with one server pulling 450W, one NAS pulling 180W, a firewall pulling 60W, two switches pulling 150W total, and ISP equipment at 50W is not a 3000VA problem. It is roughly an 890W real load before headroom. That gives enough space for startup draw, battery aging, extra equipment, and runtime planning.

A different rack may look small but draw more. Two storage-heavy servers, PoE switching, and a firewall pair can push the load up quickly. That is why Vector Digital Systems asks for the device list before quoting. We size against watts, runtime, outlet type, and shutdown behaviour. Not a guess.

Sizing rule we use in UAE racks

Keep production UPS loads below the edge of the rating. For a 2700W UPS, the practical design target is usually lower than 2700W after checking runtime target, battery age, rack heat, and future additions. Share the connected equipment list and we will size it properly.

Lithium-ion battery: why buyers choose this model

Most UPS failures in small server rooms are not caused by the inverter electronics. They are caused by batteries that were ignored. In Dubai, that happens often. A UPS is installed, the rack door stays closed, the room runs warm, and no one remembers the battery replacement date until the UPS starts beeping or drops the load during a short outage.

Lithium-ion changes that maintenance cycle. The SRTL3000RMXLI uses lithium-ion batteries with a listed life of 5 to 10 years. That does not mean you install it and forget it. It means the replacement cycle is longer than typical VRLA designs, which often become a recurring headache in warm server rooms.

For UAE businesses with many branches, this matters. A retail group with racks in Dubai, Sharjah, Abu Dhabi, and Ras Al Khaimah does not want surprise battery replacement visits every few years. A clinic chain does not want the reception server and firewall dropping because the UPS battery passed its real life two summers ago. A logistics company in JAFZA does not want the warehouse network down during a power event because the UPS passed a self-test in January and failed in August.

Lithium-ion is not the cheapest way to buy a 3kVA UPS. It is bought when battery life, space, maintenance planning, and predictable rack uptime matter.

Rack fit: 3U height, 63.9cm depth, 30.5kg weight

The SRTL3000RMXLI is a 3U rackmount UPS. That matters before you order. Some racks are already full. Some network cabinets are too shallow. Some wall-mount cabinets are not designed for a 30.5kg UPS. Some 600mm deep racks leave no room for rear cables, C19 plugs, or proper airflow.

The unit depth is 63.9cm. For a proper server rack, we normally look at 800mm or 1000mm depth depending on cabling and rear access. In a Dubai office server room, the rack itself is often the weak point. Good UPS, bad cabinet. No rear clearance. No cable management. UPS placed at the top because someone wanted it away from dust. Wrong.

A rack UPS should sit low. It is heavy, and weight belongs near the bottom of the rack. That improves stability and leaves upper space for servers, switches, patch panels, and airflow. During installation, Vector Digital Systems checks rack depth, mounting position, load balance, cable path, PDU layout, bypass requirement, and whether the AC circuit feeding the UPS is suitable.

This is standard VDS installation work. Not an add-on afterthought.

Outlet planning: 6 C13 and 2 C19

The output side gives you 6 IEC C13 and 2 IEC C19 outlets. That mix works well for many server racks. C13 covers firewalls, switches, routers, smaller servers, and network appliances. C19 covers heavier rack PDUs, larger servers, or equipment that uses higher-rated input cables.

The mistake is plugging everything directly into the UPS without planning. Better design usually means UPS output to a rack PDU, then controlled distribution to equipment. That keeps the rear of the rack cleaner and makes replacement or expansion easier. It also avoids the classic Dubai office rack problem: six devices, eight power cords, two travel adaptors, and no one knows which plug feeds the firewall.

We label the load path during deployment. UPS input. UPS output. Rack PDU. Device feed. Shutdown-connected devices. Non-shutdown devices. That matters when a technician visits the site later.

Management and shutdown

The SRTL3000RMXLI includes SmartSlot and USB compatibility. SmartSlot allows network management options, but the base model should not be assumed to include a network card unless the quoted configuration says so. That detail matters because many buyers see “SmartSlot” and think network monitoring is built in. It is not the same thing.

For a single server, USB shutdown may be enough. For a rack with virtual hosts, storage, and network equipment, a network management card is usually the better design. It lets the UPS send events across the network and allows controlled shutdown policies. In a VMware, Windows Server, Linux, or mixed environment, shutdown planning should be discussed before purchase, not after the UPS is bolted into the rack.

SmartSlot does not always mean network card included

The SRTL3000RMXLI has SmartSlot support. Network management card inclusion depends on the exact quoted variant and bundle. Ask for the network card line item if you need remote UPS monitoring, email alerts, SNMP, or controlled shutdown across multiple systems.

For small racks in Dubai, we usually ask one question: what should happen if power is still out after the first few minutes? Keep everything alive until battery exhaustion is not a plan. The proper answer may be: keep firewall and network alive, shut down storage cleanly, shut down the server after a defined timer, and send alerts to the IT team. That is how you avoid corrupted volumes and failed Monday mornings.

Power, heat, and Dubai server-room reality

A UPS is part of the cooling load. It is not just a battery. The SRTL3000RMXLI lists heat dissipation at 317 BTU/hr and noise at 50 dBA. In a proper rack room, that is manageable. In a closed storeroom with weak AC, it becomes part of the problem.

Dubai IT rooms often run hotter than the office. The thermostat may read 23°C outside the rack, while the rear of the rack is much hotter. Summer makes weak airflow obvious. A 3U UPS, one or two servers, a firewall, switches, NVR, and rack PDU can create enough heat to shorten battery and hardware life if the cabinet is badly ventilated.

The SRTL3000RMXLI operating temperature range is 0°C to 40°C. That does not mean a server room should run at 40°C. It means the equipment can operate within that range. For battery life and predictable performance, the room should be controlled properly. Especially in offices, warehouses, clinics, and hotels where IT racks are placed wherever space was available.

Vector Digital Systems checks more than the UPS model. We check the AC socket type, circuit rating, rack position, airflow path, device load, cable routing, bypass requirement, shutdown requirement, and whether the UPS should feed a rack PDU or direct outlets. Small details. Big difference when the lights flicker at 3:20PM.

Runtime must be calculated from your actual load

Do not buy this UPS based on a generic runtime claim. Runtime changes with connected watts, battery age, external battery packs, temperature, and shutdown policy. Share the equipment list and target runtime before ordering.

External runtime and battery expansion

The SRTL3000RMXLI is an extended-runtime UPS platform. That means runtime can be increased with compatible lithium-ion external battery packs, subject to the correct APC battery model and current Schneider compatibility list. For buyers, this is useful when the rack must stay online longer than the internal battery can support.

Not every rack needs extended runtime. If the requirement is clean shutdown after 10 to 15 minutes, the base UPS may be enough depending on load. If the site has generator backup and the UPS only needs to bridge generator transfer, sizing is different. If the site has no generator and the goal is 45 minutes or more, external battery planning becomes part of the quote.

For Dubai and UAE branch locations, runtime discussions need to be practical. A warehouse in JAFZA may need network and ERP access during short utility events. A clinic may need front-desk systems, firewall, and patient-record access to stay live long enough for controlled action. A trading office in DMCC may need firewall, VPN, and core switching to ride through unstable input power. Different load. Different answer.

External battery pack compatibility

Compatible lithium-ion external battery pack quantity and part number must be confirmed against the current Schneider Electric datasheet at the time of quote. Battery options change by region and product lifecycle status.

Grey market warning for APC UPS buyers in UAE

UPS hardware is one of the easiest products to list badly online. The model number looks close. The photo looks close. The price looks attractive. Then the unit arrives and it is the wrong battery type, wrong plug set, wrong outlet layout, wrong region, old stock, or a model that was never meant for your environment.

With SRTL3000RMXLI, this risk is higher because it is often confused with SRT3000RMXLI. One letter changes the product family. SRTL is lithium-ion. SRT is commonly the lead-acid Smart-UPS SRT line. The rack height, outlet count, battery system, runtime options, and replacement parts can be different.

The second issue is battery age. A UPS sitting in a warehouse is not the same as a switch sitting in a warehouse. Batteries age. Lithium-ion has a longer service profile, but stock age still matters. For production racks, the quotation should confirm current availability, valid regional warranty, correct accessory set, and whether the unit is new authorized stock.

Vector Digital Systems quotes APC UPS systems with model number clarity, region check, load sizing, and installation planning. We do not suggest the wrong UPS just because it is available on a shelf.

What Vector Digital Systems provides with the SRTL3000RMXLI

UPS sizing before quotation. Send the rack load or device list. We check the watt draw, outlet type, runtime target, shutdown needs, and whether the SRTL3000RMXLI is the right size.

Supply across all 7 UAE emirates. Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain. Office racks, server rooms, warehouses, clinics, hotels, retail branches, and data-room upgrades.

Rack installation. We mount the UPS in the correct rack position, check depth and support, route power cables cleanly, label feeds, connect the rack PDU, and test output.

Shutdown planning. USB or network-card based shutdown depends on the connected systems. We help plan shutdown order for servers, storage, virtual hosts, and network equipment.

Battery and lifecycle support. UPS support does not end on delivery. We can track battery replacement planning, firmware checks, alerts, AMC support, and replacement-unit planning for multi-site customers.

Infrastructure view. UPS, rack, server, firewall, switch, and cabling all affect each other. Vector Digital Systems has been supplying and supporting IT infrastructure in Dubai since 2009, so we quote this as part of the rack, not as an isolated box.

Stock & Availability: APC SRTL3000RMXLI available in Dubai on quote. Same-day WhatsApp pricing after model and runtime check. CTO-style UPS accessory matching available for network cards, rack PDU, bypass, external battery packs, and installation. Project quantities and FOB Dubai pricing for resellers. Ships to Africa, GCC, and South Asia.

Where this UPS fits in a Dubai rack

This UPS is a strong match for a single rack running mixed IT equipment: one or two servers, storage, firewall, router, core switch, controller, and rack PDU. It also fits small data rooms where clean online power matters but a large 6kVA or 10kVA UPS would be too much.

For a Dell PowerEdge rack, pair the UPS sizing with the server configuration. A lightly loaded 1U or 2U server is not the same as a dual-PSU server running high CPU load and multiple drives. See our Dell PowerEdge server Dubai page if this UPS is being purchased with a new rack server.

For firewall and network racks, the SRTL3000RMXLI may be more than enough power but useful because of online protection and lithium-ion lifecycle. For PoE-heavy networks, we check watt draw carefully. PoE switches can change the UPS calculation fast when cameras, access points, and phones are drawing power.

Frequently asked questions — APC SRTL3000RMXLI Dubai

Is the APC SRTL3000RMXLI a lithium-ion UPS?

Yes. The SRTL3000RMXLI is part of the APC Smart-UPS On-Line lithium-ion range. It uses lithium-ion battery technology and is rated at 3000VA / 2700W for 230V rack loads.

Is SRTL3000RMXLI the same as SRT3000RMXLI?

No. The model numbers are close, but they are not the same product. SRTL3000RMXLI is the 3U lithium-ion version with 6 IEC C13 and 2 IEC C19 outlets. SRT3000RMXLI is commonly a 2U lead-acid model. Use the full model number when requesting a UAE quote.

How much load can the SRTL3000RMXLI support?

The UPS is rated at 3000VA / 2700W. For production racks, we do not recommend sizing right at the limit. Share the server, firewall, switch, storage, and router load so we can check the watt total and runtime target.

Does this UPS include a network management card?

The SRTL3000RMXLI supports SmartSlot, but network card inclusion depends on the exact quoted variant or bundle. If you need SNMP, email alerts, web monitoring, or shutdown across multiple servers, ask us to include the correct APC network management card in the quote.

Can Vector Digital Systems install this UPS in my rack?

Yes. Installation and rack deployment are standard VDS services across all 7 UAE emirates. We check rack depth, UPS position, power input, output cabling, rack PDU connection, labels, and shutdown requirement.

Is the APC SRTL3000RMXLI available in Dubai?

Availability should be confirmed at the time of quote because UPS stock and battery-based models change by region and lifecycle status. WhatsApp the model number, quantity, and runtime target for same-day confirmation.

Comparable UPS options

APC SRT3000RMXLI: Similar 3kVA online UPS class, but typically lead-acid and 2U. Consider only when lithium-ion lifecycle is not required and the exact outlet/battery design matches the rack.

APC SRTL2200RMXLI: Lower-capacity lithium-ion online option for racks with lighter load. Good for firewall, switching, router, and one small server where 3000VA is not needed.

APC SRTL5000RMXLI: Higher-capacity lithium-ion option when the rack load is above the safe design range of 2700W or when future expansion is expected.

Rack PDU and bypass options: For production racks, the UPS quote may also need a rack PDU, maintenance bypass, network management card, and external battery pack. The UPS alone is only one part of the power design.

Africa, GCC, and MEA export from Dubai

Vector Digital Systems supplies UPS and rack power equipment for export projects across Africa, GCC, and South Asia. The SRTL3000RMXLI is suitable for branch-office racks, server-room refresh projects, telecom rooms, and IT infrastructure rollouts where 230V online UPS protection is required.

FOB Dubai pricing is available for resellers, contractors, and end customers. We can quote UPS units with rack PDUs, network cards, external battery packs, server racks, and Dell PowerEdge servers in the same project. Common export requests include Kenya, Tanzania, Uganda, Nigeria, Qatar, Oman, Iraq, and Maldives.

For export, share the destination country, quantity, runtime target, and whether the site needs 220V, 230V, or 240V output configuration. We will confirm availability, packing, documentation, and shipping options from Dubai.

About Vector Digital Systems — Dubai IT Infrastructure Partner

Vector Digital Systems supplies the APC SRTL3000RMXLI with UPS sizing, rack deployment, power cabling, server-room installation, and IT infrastructure support across all 7 UAE emirates — Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain. APC UPS systems can be quoted with Dell PowerEdge servers, rack PDUs, firewall projects, and AMC support. Export to Africa, GCC, and international markets — FOB Dubai pricing on request. Operating since 2009. Contact: +971 4 450 4145 · Monday–Saturday 8AM–6PM.

Get a quote for APC SRTL3000RMXLI

Dubai quote · UPS sizing · Rack installation · Runtime check · UAE and export projects