Description
APC Smart-UPS On-Line SRTG10KXLI 10kVA/10kW Rack/Tower UPS Dubai
When one rack outage stops the office
The server is fine. The firewall is fine. The storage is fine. Then DEWA power drops for a few seconds, the generator takes time to pick up, and everything in the rack reboots in the wrong order.
That is the moment most Dubai businesses start looking properly at UPS sizing. Not the small 1kVA unit under a desk. Not the old UPS with batteries nobody has tested since 2021. A real online UPS for the server rack, with enough output capacity, remote management, and proper site installation.
The APC Smart-UPS On-Line SRTG10KXLI is built for that job. It is a 10kVA / 10kW double-conversion online UPS for rack and tower deployment, running at 230V with hardwire input, hardwire output support, IEC outlets, and Network Management Card 3 included. It is not a plug-and-play desk UPS. It is infrastructure equipment for server rooms, network rooms, storage racks, CCTV back-end rooms, and small data centre cabinets.
Vector Digital Systems supplies, installs, and supports APC UPS systems across all 7 UAE emirates. Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain. We size the UPS against the load, check the rack space, plan electrical readiness, and handle installation so the unit is not left sitting in a box while the electrician asks where the input cable should go.
10kW output — not just 10kVA on paper
The SRTG10KXLI is rated at 10,000VA and 10,000W. That 1.0 power factor matters when you are backing up dense IT loads such as Dell PowerEdge servers, storage arrays, firewalls, switches, NVRs, IP PBX, and virtualization hosts. Always size the UPS from actual watt load, not only the number of devices in the rack.
What the APC SRTG10KXLI is built for
This UPS sits in the serious part of the APC Smart-UPS On-Line range. It is made for sites where downtime costs more than the UPS. A trading office in Business Bay with two racks. A JAFZA logistics company running ERP, file services, CCTV recording, and warehouse switches. A clinic in Dubai with patient records, firewall, Wi-Fi controller, and storage in one server cabinet. A hotel back-office rack with PMS, IP PBX, access control, CCTV, and core switching.
The SRTG10KXLI is also the right fit for businesses that already know the difference between backup time and power quality. Small UPS units can keep power flowing for a few minutes. A double-conversion online UPS does more than that. It constantly converts incoming AC power to DC and back to clean AC output, isolating connected equipment from voltage drops, spikes, unstable mains input, and transfer delays.
That matters in Dubai. Server rooms often sit inside offices, warehouse mezzanines, retail branches, or older commercial buildings. Cooling is not always data-centre grade. Power loads change when air conditioning starts, lifts switch, or generators come online. Etisalat and du connectivity can stay active, but your rack still needs stable power for the firewall, router, switches, and servers to remain reachable.
This is why we position the APC SRTG10KXLI as a rack power protection unit, not a general office UPS. It belongs where the load is planned, the electrical input is prepared, and the battery runtime is calculated before purchase.
APC Smart-UPS On-Line SRTG10KXLI specifications
| Specification | Detail |
|---|---|
| Product Name | APC Smart-UPS On-Line SRTG10KXLI 10kVA/10kW Rack/Tower UPS |
| UPS Topology | Double-conversion online |
| Output Capacity | 10,000VA / 10,000W |
| Nominal Output Voltage | 230V, configurable for 220V / 230V / 240V |
| Nominal Input Voltage | 230V, with 220V / 240V support |
| Input Connection | Hard wire 3-wire, 1P + N + E |
| Output Connections | 2x IEC 60320 C13, 1x IEC 60320 C19, 1x hard wire 3-wire H + N + E |
| Waveform | Sine wave |
| Efficiency | 93.5% |
| Rack Height | 5U |
| Dimensions | 217mm H x 440mm W x 680mm D |
| Net Weight | 101.5kg |
| Battery Type | Lead-acid battery |
| Replacement Battery | APCRBC174 |
| Battery Recharge Time | 4 hours |
| Battery Life | 3 to 5 years, depending on temperature and use |
| Management | Network Management Card 3 with environmental monitoring |
| Emergency Power Off | Yes |
| Noise Level | 55 dBA |
| Heat Dissipation | 2217.98 Btu/h |
| Operating Temperature | 0°C to 40°C |
| Warranty | 3 years repair or replace excluding battery, 2 years battery warranty |
Hardwire electrical work is required
The SRTG10KXLI uses hard wire 3-wire input. Do not order this unit assuming it plugs into a standard wall socket. Site electrical readiness must be checked before delivery, especially for server rooms in office towers, warehouses, clinics, hotels, and retail back-office racks.
Why double-conversion online UPS matters
There are three questions we ask before quoting a UPS: what is the load, how long must it stay online, and what happens when it shuts down badly?
A small line-interactive UPS may be enough for one workstation, one router, or a reception PC. A 10kVA rack load is different. You may have two Dell servers, one storage unit, FortiGate firewall, core switch, access switches, NVR, IP PBX, NAS, and ISP equipment in the same rack. When mains power becomes unstable, each device reacts differently. Some ride through. Some reboot. Some freeze. Some return with services in the wrong order.
The SRTG10KXLI avoids that by feeding the rack from its inverter at all times. Incoming utility power charges the DC bus and battery system. The inverter then produces the AC output. That design gives connected equipment cleaner power and removes transfer delay during power events. For business systems, that is the point.
This is especially useful where the rack supports operations, not just IT. A JAFZA warehouse cannot pause barcode scanning every time the power flickers. A DAFZA office cannot have firewall and VPN services reboot during a client call. A Dubai hotel cannot keep the front desk waiting while the PBX, access control, and back-office server restart. Power protection is boring until the first outage. After that, it becomes the item nobody wants to compromise again.
Rack planning: 5U, 680mm depth, 101.5kg weight
The APC SRTG10KXLI is a rack/tower UPS, but the rack part needs planning. It occupies 5U of rack height. The chassis depth is 680mm. Net weight is 101.5kg. That is before you think about external battery packs, cable bend radius, rack PDU placement, or service access.
For a standard Dubai server cabinet, we normally check three things before installation. First, usable rack depth. A 600mm wall-mounted rack is not suitable. A 1000mm or 1200mm floor-standing server cabinet is the normal fit. Second, load rating. The UPS should sit low in the rack because of the weight. Not above head height. Not on weak shelves. Third, airflow. The UPS releases heat, and the rack room needs working cooling.
The heat output number is not just datasheet trivia. At 2217.98 Btu/h, this UPS adds thermal load inside the server room. In Dubai, where outside temperatures hit 45°C and office AC can be switched off overnight, the UPS room must be treated as an IT room. Battery life drops fast in heat. A battery that should run for 3 to 5 years can age early if the room sits warm every weekend.
Vector Digital Systems checks rack position, cable path, input supply, output distribution, cooling condition, and management access before handover. A 10kVA UPS is not just delivered. It is installed into a working power path.
Input, output, and what your electrician needs to know
The SRTG10KXLI is a 230V unit with hardwire 3-wire input: single phase, neutral, and earth. Output is also practical for mixed rack environments. You get 2 IEC C13 outlets, 1 IEC C19 outlet, and a hard wire 3-wire output connection. Many buyers miss this detail and expect the UPS to feed every device directly from rear sockets. In real installations, the UPS often feeds a rack PDU or a hardwired distribution path.
This is where site work matters. A 10kVA UPS must be connected to the correct input breaker and cable size. The earth must be correct. The rack load must be split properly. Output cabling should match the connected load and rack layout. If the UPS is backing up both IT and CCTV, or both server rack and network rack, the distribution should be drawn before installation.
We normally ask for photos of the electrical DB, server rack, existing UPS, and equipment labels before quoting installation. For larger sites, we schedule a visit. It saves time. It prevents the common UAE problem: UPS delivered, rack ready, but no correct electrical point available.
NMC3 management — remote UPS visibility
The SRTG10KXLI includes Network Management Card 3 with environmental monitoring. Your IT team can monitor UPS status, battery state, input/output conditions, alerts, and shutdown events over the network. For Dubai offices with shared IT support, NMC3 is the difference between finding out early and finding out after the rack shuts down.
Network Management Card 3 and remote alerts
Remote management is one of the main reasons to buy the SRTG10KXLI instead of a basic UPS. The included NMC3 card gives the UPS its own network identity. Your IT team can log in, check load percentage, battery health, input voltage, output status, alarm history, and environmental data. Alerts can be configured so the right person knows when there is a power event, battery issue, overload, bypass condition, or temperature concern.
For sites without a full-time IT engineer, this matters. A Dubai branch office may have only admin staff onsite. A Ras Al Khaimah warehouse may depend on remote IT from head office. An Abu Dhabi clinic may call support only when systems are already down. With NMC3 configured correctly, the UPS reports problems before the business notices the effect.
It also helps with planned shutdown. If the power outage exceeds runtime, connected servers and storage should shut down in a controlled sequence. That is much better than a hard power cut under load. Databases, virtual machines, file shares, CCTV archives, and Windows Server volumes do not like sudden shutdowns.
Vector Digital Systems configures network management during installation. IP address, access credentials, alert email, time settings, firmware check, load reading, and battery status. We do not leave the management card at default settings and call the job finished.
Battery planning and APCRBC174 replacement
The SRTG10KXLI uses lead-acid batteries, with APCRBC174 as the replacement battery cartridge. Battery life is typically 3 to 5 years, but the room temperature decides how close you get to the higher number. In a cooled server room, batteries last longer. In a warm rack room behind a warehouse office, they age faster.
Battery runtime is not a fixed number. It depends on the connected load. A UPS running at 20 percent load stays up longer than the same UPS running at 80 percent load. That sounds obvious, but many quotes ignore it. We ask for the load because the backup time depends on it. Server model, power supply count, storage type, switch count, firewall model, NVR load, monitor load if any, and whether the UPS must support one rack or two.
For some Dubai offices, the target is 10 to 15 minutes — enough time for generator transfer or controlled shutdown. For others, especially warehouses and branch sites, the target may be 30 minutes or more. Extended runtime planning needs proper battery configuration, not guesswork.
We can quote the UPS alone, or UPS with installation, battery replacement plan, network management setup, and annual maintenance support. The right scope depends on how critical the rack is to your business.
Power, cooling, and the Dubai server room reality
A 10kVA UPS is not something you add to a rack at the end of the project. It affects electrical load, rack layout, cooling, cable routing, shutdown planning, and maintenance access. The APC SRTG10KXLI is rated for 0°C to 40°C operation, but that does not mean a warm storage room is acceptable. Battery health drops when the room sits hot. Fast.
Dubai sites are different from brochure conditions. Many server rooms are converted office corners. Some are inside warehouse mezzanines in Al Quoz, DIP, JAFZA, or Ras Al Khor. Some racks sit near glass partitions with office AC cycling on a timer. At 10kVA, the UPS itself adds heat — 2217.98 Btu/h. That heat must be removed from the room, not trapped behind the rack.
We check cooling before installation because battery replacement is usually more expensive than fixing airflow early. The UPS should sit low in the rack, with enough rear clearance for power cables and ventilation. The room should stay cool overnight and during weekends. A rack with Dell PowerEdge servers, FortiGate firewall, switches, storage, NVR, and PBX cannot depend on office-hours AC.
For Etisalat and du handoff racks, the same rule applies. Keeping the ISP router alive is not enough. The firewall, switch stack, Wi-Fi controller, server, and storage also need stable power. One missed device can break the chain.
Stock & Availability: APC SRTG10KXLI available in Dubai. Same-day quote on WhatsApp. Ready-stock and project quantity options. Installation, electrical coordination, NMC3 setup, battery planning, and AMC support available across UAE. FOB Dubai pricing for Africa, GCC, and South Asia export.
Grey market UPS warning — batteries, warranty, and service tags
UPS grey market risk is different from laptop grey market risk. With a UPS, the hidden problem is often battery age, region warranty, missing accessories, or units stored badly before sale. The outside looks new. The battery may not be.
For a 10kVA online UPS, that matters. A unit that sat in a hot warehouse for months can reach your site with weaker batteries. A unit imported outside the normal channel may not have proper local warranty handling. A unit sold without correct rails, manuals, or installation planning can delay the whole rack project.
The APC SRTG10KXLI uses APCRBC174 replacement batteries. That part number should be known before purchase, not discovered after the first battery alarm. Battery cost, replacement lead time, and maintenance access all affect the life cost of the UPS.
Vector Digital Systems supplies APC UPS systems through authorised UAE channels where available, checks model details before delivery, and supports installation after supply. We do not treat the UPS as a box shipment. For 10kVA loads, the supply path and the site work both matter.
Do not buy 10kVA UPS by price only
Ask for the exact model number, battery condition, warranty terms, input type, output type, rack kit status, and installation scope. A cheaper UPS can cost more once cabling, batteries, shutdown setup, and site work are added later.
What Vector Digital Systems provides with the APC SRTG10KXLI
UPS sizing before quote. We ask for the real rack load before recommending a unit. Server count, firewall model, switch count, storage, CCTV NVR, PBX, access control, ISP equipment, and required backup time. A 10kVA UPS may be right. Or you may need less. Or more runtime through battery expansion.
Site readiness check. The SRTG10KXLI uses hardwire input. We check electrical DB, breaker readiness, rack position, cable path, earthing, rack depth, and available 5U space before installation. For Dubai office towers, free zones, clinics, and warehouses, this prevents delivery-day surprises.
Rack deployment. The unit weighs 101.5kg, so rack placement is not casual. We install it low in the rack, plan rear cable clearance, connect output distribution, and label the power path. Installation and rack deployment are standard VDS services.
Network management setup. The included NMC3 card is configured with IP settings, secure access, alerting, date/time, load status, battery state, and event checks. Your IT team should be able to see the UPS remotely on day one.
Server shutdown planning. Where required, we coordinate shutdown rules for servers, storage, and virtual machines. The goal is simple: if the outage lasts longer than runtime, systems shut down cleanly instead of crashing under load.
Battery and AMC support. We support battery replacement planning, health checks, runtime tests, alert review, and scheduled maintenance. UPS batteries are not fit-and-forget parts. In UAE heat, they need attention.
Vector Digital Systems has been operating in Dubai since 2009. We supply UPS, Dell PowerEdge servers, firewalls, switching, PBX, CCTV, and support contracts across all 7 emirates. One rack. One team. Less finger-pointing when power, network, and server issues overlap.
Availability, quote, and installation scope
APC SRTG10KXLI pricing in UAE depends on availability, warranty terms, project quantity, installation scope, and whether extra electrical work or battery runtime planning is required. We do not display a fixed AED price for this reason. A box-only quote and an installed UPS project are not the same purchase.
For a quote, send the connected load list and required backup time on WhatsApp. A photo of the rack helps. A photo of the existing UPS helps more. If this is a new server room, share the rack size, electrical DB location, and whether the UPS will feed one rack or multiple racks.
Ready-stock options may be available in Dubai. CTO and project quantity supply depends on live distributor stock. For business-critical sites, we can include installation, battery health check, NMC3 configuration, and AMC support in the same proposal.
Frequently asked questions — APC SRTG10KXLI Dubai
Is the APC SRTG10KXLI a 10kVA or 10kW UPS?
It is both: 10,000VA and 10,000W. That 1.0 output power factor makes it suitable for dense IT racks where the load is measured in watts, not just VA. We still size the UPS from actual equipment load before quoting.
Can this UPS plug into a normal wall socket?
No. The SRTG10KXLI uses hard wire 3-wire input: single phase, neutral, and earth. It needs proper electrical preparation, breaker sizing, earthing, and installation by qualified technicians. This is not a desk UPS.
How much rack space does the SRTG10KXLI need?
It occupies 5U and has a 680mm chassis depth. Net weight is 101.5kg, so it should be installed low in a suitable floor-standing rack. A shallow wall cabinet is not suitable for this model.
Does it include remote monitoring?
Yes. The APC SRTG10KXLI includes Network Management Card 3 with environmental monitoring. We configure IP access, alerts, status checks, and handover during installation when VDS handles deployment.
What battery does the SRTG10KXLI use?
The replacement battery cartridge is APCRBC174. Battery life is typically 3 to 5 years, depending on temperature and usage. In Dubai server rooms, cooling has a direct effect on battery life.
Is the APC SRTG10KXLI available in Dubai?
Availability changes by distributor stock and project quantity. Vector Digital Systems can quote ready-stock or project supply, with installation across Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain.
Comparable APC UPS options
APC Smart-UPS On-Line 6kVA: Right when the rack load is lower and the site does not need 10kW output. Often used for smaller server racks, CCTV rooms, and network cabinets.
APC Smart-UPS On-Line 8kVA: A middle option when 6kVA is tight but 10kVA is more than the load requires. Useful for one rack with moderate server and network equipment.
APC Smart-UPS On-Line 15kVA: Consider this when the connected load, growth plan, or runtime target exceeds what 10kVA can safely cover. Common for larger server rooms and multi-rack setups.
Dell PowerEdge rack projects: If the UPS is being purchased for a new server rack, see our Dell PowerEdge server range in Dubai. We can quote server, UPS, firewall, switching, rack, cabling, and installation as one project.
Africa, GCC, and MEA export from Dubai
Vector Digital Systems can support APC UPS export enquiries from Africa, GCC, and South Asia on FOB Dubai terms. Common project destinations include Kenya, Tanzania, Uganda, Nigeria, Oman, Qatar, Saudi Arabia, and Iraq. For 10kVA UPS orders, we confirm model, battery condition, packing, weight, and documentation before shipment.
UPS export needs planning because batteries affect logistics. Share the destination country, quantity, required warranty terms, and whether the order is for a data centre, branch rollout, warehouse, or telecom site. Export quotes are handled separately from UAE installation quotes.
About Vector Digital Systems — APC UPS and Dell infrastructure partner
Vector Digital Systems supplies the APC Smart-UPS On-Line SRTG10KXLI in Dubai, UAE, with UPS sizing, installation, rack deployment, NMC3 setup, battery planning, and support across all 7 UAE emirates — Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, and Umm Al Quwain. We also supply Dell PowerEdge servers, firewalls, switching, racks, CCTV, IP PBX, and AMC services. Operating since 2009. Contact: +971 4 450 4145 · Monday–Saturday 8AM–6PM.
Get a quote for APC SRTG10KXLI Dubai
10kVA / 10kW online UPS · Rack/tower 5U · NMC3 included · Installation and project pricing on WhatsApp